Expansion boards UPP et al .

A device for printing protocols to a printer (SCP).
- The SCP is designed to print the archives of the heat meter on a Russified matrix printer that supports the Epson command system. The printer is connected using a Centronics type cable directly to the SB-04 (or UPR). The SCP board is installed in the XS5 slot of the SB-04 motherboard (or SCP).
- The USB card installed in the XS6 SB-04 slot provides automatic recording of the heat meter archive to a flash disk in the form of a file. The archive is read from the flash disk to the thermal accounting database using free software.
- Designed to work as part of an information network with an RS-485 interface. The boards are installed in any slots of the SB-04 motherboard (or UPR). Additionally, the board provides the values of the measured parameters, information about the heat meter and the current values of the integrators via the MODBUS interface (RTU and ASCII). Protocol recognition is performed automatically.
- Designed to work as part of an information network with an RS-485 interface. The boards are installed in any slots of the SB-04 motherboard (or UPR). Additionally, the board provides the values of the measured parameters, information about the heat meter and the current values of the integrators via the MODBUS interface (RTU and ASCII). Protocol recognition is performed automatically.
- The LonWorks interface card is designed to connect the heat meter to LonWorks networks. The board is installed in any of the three pairs of slots of the SB-04 motherboard. Once a second, it requests data from the MP heat meter (instantaneous values of measured parameters and current values of integrators), presents them in the format of “Standard Network Variables” (SNVT) of the LON system and transmits these variables to the network. The board is available in four versions: LonWorks–1, LonWorks–2, LonWorks–3 and LonWorks–4. The number in its name indicates the number of LonWorks network nodes supported by the board. Each node provides data transmission to the network of one heat meter metering unit.
- It is intended for issuing to an external consumer from one to four values of the current measured parameters of the heat meter in the form of standard signals of current outputs with ranges of 0-5, 0-20 or 4-20 mA. PTV is installed in any slot of the SB-04 motherboard (or UPR). The board is available in four versions: PTV-1, PTV-2, PTV-3 and PTV-4. The number in its name indicates the maximum number of current output signals generated by the board.
- Designed to regulate the temperature of the coolant. The control board (PR) is an expansion board for a heat meter. The board can be installed in any of the 6 slots on the SB-04 motherboard.
- The digital input board (eight-channel) is designed to read the status and count the switching of external sensors (fire alarm, access to the room, etc.) having an output of the "dry contact" or "open collector" type. It is used in conjunction with the GSM modem card to expand the functionality of the SB when working in the control system of the CEN. The board is installed in any slot of the SB-04 motherboard.
- The digital output board is designed to output states having two logical values to external devices. An additional feature is the generation of frequency up to 500 Hz with a period setting step of 1 ms. The board is installed in any slot of the SB-04 motherboard.
All products
The group "New Technologies" offers for review the products of the plant : production of heat meters, commercial metering devices for heat energy and liquid flow
About
The priority area of the company's activity is the development, creation, implementation of energy accounting systems in housing and communal services and industry of the Russian Federation and CIS countries.
-
COMMERCIAL ENERGY ACCOUNTING
Reduction of electricity costs. The reliability of the data. Automated processes. Continuous collection of readings. -
LIQUID FLOW ACCOUNTING
Optimization of fluid flow measurements. Versatility. High accuracy and reliability. Modularity of the design and flexibility of the configuration. -
DISPATCHING
Automated control and accounting of energy resources: heat, water, steam, gas, electricity.
NEW TECHNOLOGIES GROUP
For sales and support please contact
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89
Send your question now: